7 research outputs found

    Risk Factors Affecting the Survival Rate of Collagen Meniscal Implant for Partial Meniscal Deficiency: An Analysis of 156 Consecutive Cases at a Mean 10 Years of Follow-up

    Get PDF
    Background: Collagen meniscal implant (CMI) is a biologic scaffold that can be used to replace meniscus host tissue after partial meniscectomy. The short-term results of this procedure have already been described; however, little is known about risk factors for failure. Purpose: To determine the factors that predict failure of meniscal scaffold implantation in a large series of patients treated at a single institution and to better define the indications for surgery. Study Design: Case-control study; Level of evidence, 3. Methods: The analysis included 186 consecutive patients with a minimum 5-year follow-up who underwent CMI scaffold implantation or combined procedures. Patients' characteristics and details of the surgery were obtained via chart review. Patients with a Lysholm score Results: The final analysis included 156 patients (84%) at a mean follow-up of 10.9 +/- 4.3 years. The patients' mean age at surgery was 42.0 +/- 11.1 years, and the survival rate was 87.8%. Subgroup analysis identified Outerbridge grade 3-4 (Hazard ratio [HR], 3.8; P = .004) and a lateral meniscal implant (HR, 3.2; P = .048) as risk factors for failure. The survival rate was 90.4% for medial implants and 77.4% for lateral implants. An Outerbridge grade 3-4 (HR, 2.8; P < .001) and time from meniscectomy to scaffold >10 years (HR, 2.8; P = .020) were predictive of surgical or clinical failure. Conclusion: CMI for partial meniscal deficiency provided good long-term results, with 87.8% of the implants still in situ at a mean 10.9 years of follow-up. Outerbridge grade 3-4, lateral meniscal implants, and longer time from the meniscectomy to implantation of the CMI were identified as risk factors for clinical and surgical failure

    Custom-Made Devices Represent a Promising Tool to Increase Correction Accuracy of High Tibial Osteotomy: A Systematic Review of the Literature and Presentation of Pilot Cases with a New 3D-Printed System

    Get PDF
    Background: The accuracy of the coronal alignment corrections using conventional high tibial osteotomy (HTO) falls short, and multiplanar deformities of the tibia require consideration of both the coronal and sagittal planes. Patient-specific instrumentations have been introduced to improve the control of the correction. Clear evidence about customized devices for HTO and their correction accuracy lacks. Methods: The databases PUBMED and EMBASE were systematically screened for human and cadaveric studies about the use of customized devices for high tibial osteotomy and their outcomes concerning correction accuracy. Furthermore, a 3D-printed customized system for valgus HTO with three pilot cases at one-year follow-up was presented. Results: 28 studies were included. The most commonly used custom-made devices for HTO were found to be cutting guides. Reported differences between the achieved and targeted correction of hip-knee-ankle angle and the posterior tibial slope were 3 degrees or under. The three pilot cases that underwent personalized HTO with a new 3D-printed device presented satisfactory alignment and clinical outcomes at one-year follow-up. Conclusion: The available patient-specific devices described in the literature, including the one used in the preliminary cases of the current study, showed promising results in increasing the accuracy of correction in HTO procedure

    Lateral unicompartmental knee arthroplasty (UKA) showed a lower risk of failure compared to medial unicompartmental knee arthroplasty in the Register of Prosthetic Orthopedic Implants (RIPO)

    Get PDF
    The present study aimed to investigate differences in survivorship between medial and lateral unicompartmental knee arthroplasty (UKA) by analyzing the data of an Italian regional registry. The hypothesis was that, according to recent literature, lateral implants have comparable survivorship with regard to the medial implants

    The 25-year experience of over-the-top ACL reconstruction plus extra-articular lateral tenodesis with hamstring tendon grafts: the story so far

    No full text
    Abstract This article presents with an evidence based approach, the kinematical rationale, biological evidence and the long term results of the “Over-The-Top” anterior cruciate ligament reconstruction with lateral plasty technique. This surgery was developed more than 25 years ago at the Rizzoli Institute by professor Marcacci and Zaffagnini and it is still widely performed in many orthopedic center worldwide

    Correction to: Tocilizumab for patients with COVID-19 pneumonia. The single-arm TOCIVID-19 prospective trial

    No full text
    corecore